G6K-2F-RF-V
Surface-mounting High-frequency Relay
8-GHz Band Miniature DPDT
High Frequency Relay for High-speed
Differential Transmission Signal
Switching
• High-frequency characteristics (insertion loss 3 dB or less at 8 GHz)
• Miniaturized to 11.7 × 7.9 × 7.1 mm (L × W × H).
• Rated power consumption of 100 mW with high sensitivity
RoHS Compliant
■Model Number Legend
Application Examples
• Semiconductor test equipment
• Test&measurement equipment
• Communication equipment
G6K-2F-RF-V
—— — —
12 3 4
1. Number of poles/
Contact Form
2: 2-pole/ DPDT (2c)
3. Special Function 1
RF: High-frequency compatible
G
6
K
2
F
R
F
V
Contact type: Bifurcated crossbar
Ag (Surface Au alloy)
-
2. Terminal Shape
F: Outside-L surface mounting
terminals
■Standard type specifications
4. Special Function 2
V: 8-GHz band
High-speed differential transmission compatible type
-
Note. We have a lineup of G6K (U)-2F(P)-RF(-S,-T) products for 1-GHz/3-GHz band high-frequency signal applications.
-
■Ordering Information
Relay Function
Enclosure rating
Contact form
Model
Rated coil voltage
Single-side stable
Fully sealed
DPDT (2c)
G6K-2F-RF-V
4.5, 5, 12 VDC
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G6K-2F-RF-V DC5
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
Minimum packing unit
40 pcs/tube
■Ratings
●Contacts
Item
Rated load
Rated carry current
Max. switching voltage
Max. switching current
●High-frequency Characteristics *1
Load
Resistive load
125 VAC, 0.3 A
30 VDC, 1 A
10 VDC, 10 mA
8 GHz, 1 W *
1A
125 VAC or 60 VDC
1A
* This value is for a V.SWR of 1.2 max. at the load.
Item
Differential
transmission
characteristics
Single-ended
characteristics
(reference value)
Frequency
8GHz
Insertion loss
3 dB max.
Isolation
15 dB min.
Return loss (V.SWR)
5 dB min. (3.57 max.)
Insertion loss
4 dB max.
Isolation
Between contacts of
the same polarity
15 dB min.
Between contacts of
different polarity
15 dB min.
Return loss (V.SWR)
5 dB min. (3.57 max.)
Maximum carry power
1 W *2
Maximum switching power
1 W *2
Note 1. The impedance of the measurement system is 50 Ω. (Differential impedance is 100 Ω.)
Note 2. The above values are initial values.
*1. Contact your OMRON representative if the Relay will be used in an
application that requires high repeatability in high-frequency
characteristics.
*2. These values are for a V.SWR of 1.2 max. at the load.
1
G6K-2F-RF-V
Surface-mounting High-frequency Relay
●Coil: Single
Item
Rated voltage
Rated current
(mA)
Coil resistance
(Ω)
4.5 VDC
23.2
5 VDC
21.1
237
12 VDC
9.1
1,315
Must operate voltage Must release voltage
(V)
(V)
Maximum voltage
(V)
% of rated voltage
Power consumption
(mW)
194
80% max.
10% min.
150%
Approx. 100
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
■Characteristics
-
G
6
K
2
F
R
F
V
Contact resistance *1
Operating time *2
Release time *2
Insulation resistance *3
Between coil and
contacts
Between contacts of
different polarity
Dielectric
strength
Between contacts of the
same polarity
Between ground and
coil/contacts
Destruction
Vibration
resistance
Malfunction
Destruction
Shock
resistance
Malfunction
Mechanical
Durability
Electrical
100 mΩ max.
3 ms max. (approx. 1.4 ms)
3 ms max. (approx. 0.7 ms)
500 MΩ min. (at 500 VDC)
350 VAC, 50/60 Hz for 1 min
350 VAC, 50/60 Hz for 1 min
350 VAC, 50/60 Hz for 1 min
350 VAC, 50/60 Hz for 1 min
-
10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude)
10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude)
1,000 m/s2
750 m/s2
50,000,000 operations min. (at a switching frequency of 36,000 operations/hour)
1,000,000 operations min. (10 VDC, 10 mA, at a switching frequency of 1,800 operations/hour)
100,000 operations min. (Other rated load, at a switching frequency of 1,800 operations/hour)
-40°C to 70°C (with no icing or condensation)
5% to 85%
Approx. 1.16 g
Ambient operating temperature
Ambient operating humidity
Weight
Note. The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
*2. Values in parentheses are actual values.
*3. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength.
2
G6K-2F-RF-V
Surface-mounting High-frequency Relay
■Engineering Data
●High-frequency characteristics (differential transmission characteristics)
Insertion loss
Isolation
1
2
3
0
Return loss (dB)
Isolation (dB)
Insertion loss (dB)
0
Return loss, V.SWR
Sample: G6K-2F-RF-V
10
N.O.
N.C.
5
Sample: G6K-2F-RF-V
5
4.5
10
4
Return loss
20
30
6
15
3.5
20
3
V.SWR
25
V.SWR
4
5
0
2.5
40
7
N.O.
N.C.
8
10
0
2
35
1.5
40
60
1
2
3
4
5
6
7
8
9
0
10 11 12
1
2
3
4
5
6
7
8
Frequency (GHz)
Isolation (dB)
1
2
0
2
3
4
5
6
7
8
1
9 10 11 12
Frequency (GHz)
Sample: G6K-2F-RF-V
10
0
N.O.
N.C.
5
4.5
4
Return loss
15
3.5
3
V.SWR
6
2.5
30
2
35
1.5
-
25
40
7
N.O.
N.C.
8
9
N.O.
N.C.
50
Sample: G6K-2F-RF-V
10
0
1
2
3
4
5
6
7
8
9 10 11 12
Frequency (GHz)
60
0
G
6
K
2
F
R
F
V
-
20
30
V.SWR
4
5
-
20
Sample: G6K-2F-RF-V
10
3
5
1
Return loss, V.SWR
0
0
9 10 11 12
Frequency (GHz)
●High-frequency characteristics (single-ended characteristics)
Insertion loss
Isolation
Insertion loss (dB)
30
Sample: G6K-2F-RF-V
Return loss (dB)
9
N.O.
N.C.
50
40
1
2
3
4
5
6
7
8
9 10 11 12
Frequency (GHz)
0
1
2
3
4
5
6
7
1
8 9 10 11 12
Frequency (GHz)
Note 1. The high-frequency characteristics depend on the mounting board. Be sure to check operation including durability in actual equipment before use.
Note 2. Ambient temperature condition: 23°C.
Note 3. The impedance of the measurement system is 50 Ω. (Differential impedance is 100 Ω.)
Note 4. S parameter (Touchstone format) data used for circuit simulation is available. Please inquire.
3
G6K-2F-RF-V
Surface-mounting High-frequency Relay
250
250
250
150
150
150
100
100
100
50
50
50
0
0
0
-50
50
100
150
200
250
Time (ps)
200
-50
-100
0
300
200
-100
-100
0
20
40
60
80 100
120 140 160 180 200
Time (ps)
0
20
40
60
100
80
120
140 160
Time (ps)
Eye Height
Eye Width
Jitter P-P
Eye Height
Eye Width
Jitter P-P
Eye Height
Eye Width
Jitter P-P
173 mV
121.0 ps
2.5 ps
177 mV
96.5 ps
3.5 ps
147 mV
75.2 ps
4.8 ps
300
250
N.C. Contact
300
250
Voltage (mV)
N.C. Contact
Voltage (mV)
N.C. Contact
Voltage (mV)
300
200
-50
300
250
200
200
200
150
150
150
100
100
100
50
50
50
0
0
0
-50
-50
-50
-
G
6
K
2
F
R
F
V
at 12.5 Gbps
N.O. Contact
Voltage (mV)
300
Voltage (mV)
Voltage (mV)
●High-frequency characteristics (Signal Integrity, differential transmission)
at 8.1 Gbps
at 10 Gbps
N.O. Contact
N.O. Contact
-
-100
-100
-100
0
50
100
150
200
250
Time (ps)
0
20
40
60
80 100
0
120 140 160 180 200
Time (ps)
20
40
60
100
80
140 160
Time (ps)
Eye Height
Eye Width
Jitter P-P
Eye Height
Eye Width
Jitter P-P
Eye Height
Eye Width
Jitter P-P
166 mV
116.0 ps
7.4 ps
172 mV
94.5 ps
5.5 ps
137 mV
74.4 ps
5.6 ps
Conditions
• 211-1 PRBS signal
• Input differential voltage 200 mV
• Rise time 25 ps @10 - 90%
Note 1. Ambient temperature condition: 23°C.
Note 2. The impedance of the measurement system is 50 Ω. (Differential impedance is 100 Ω.)
Note 3. This data includes loss due to the test board.
●Propagation delay time
Item
Propagation delay time (ps)
N.O. Contact
107.5
N.C. Contact
115.0
(typical value)
Note 1. Ambient temperature condition: 23°C.
Note 2. The impedance of the measurement system is 50 Ω. (Differential impedance is 100 Ω.)
Conditions
Relay input
Voltage
waveform
Rise time 25 ps @10 - 90%
90%
50%
10%
Time
Relay output
waveform
Voltage
50%
Time
Propagation delay time
4
120
G6K-2F-RF-V
Surface-mounting High-frequency Relay
■Dimensions
(Unit: mm)
G6K-2F-RF-V
Mounting Dimensions (Top View)
Tolerance: ±0.1 mm
11.7±0.2
7.9±0.2
7.1
0.15
1.27
2.54
0.4±0.1
(0.76)
(1.68)
(5.08)
3.81
5.08
6.35
2.54
1.27
10.16
8.89
7.62
6.35
5.08
3.81
Terminal Arrangement/
Internal Connections
TOP VIEW
Orientation mark
8
7
6
5
2
3
4
−
+
1
8.3±0.2
7.62
8.89
10.16
(9.2)
4.24
Note. Check carefully the coil
polarity of the Relay.
Note 1. Each value has a tolerance of ±0.3 mm.
0.7
Note 2. The coplanarity of the terminals is 0.15 mm max.
Note 3. The dimensions of the printed circuit board work drawing are a recommended example that take soldering into consideration. Frequency characteristics vary depending on the band dimensions, so check
the effect on high-frequency characteristics using a test board before use.
■Package specifications
Tube Packing
G6K-2F-RF-V in tube packing are arranged so that the orientation mark of each Relay in on the left side.
Be sure not to make mistakes in Relay orientation when mounting the Relay to the PCB.
Orientation of Relays
-
Stopper
(gray)
G
6
K
2
F
R
F
V
Stopper
(green)
-
Tube length: 520 mm (stopper not included)
No. of Relays per tube: 40 pcs
5
G6K-2F-RF-V
Surface-mounting High-frequency Relay
■G6K-2F-RF-V Recommended Soldering Method
Temperature (°C)
●Recommended Conditions for IRS Method (Surface-mounting Terminals)
• The thickness of cream solder to be applied should be
(1) IRS Method (Mounting Solder: Lead)
between 200 and 250 μm and the land pattern should be
based on OMRON’s recommended PCB pattern.
• To maintain the correct soldering joint shown in the following
diagram, we recommend applying solder with the soldering
conditions shown on the left.
Soldering
220~
245
Correct Soldering
180~
200
Incorrect Soldering
Relay
Terminal
Land
Preheating
150
Heel fillet is
formed
PCB
Solder
90~120
(The temperature profile indicates the temperature on the circuit board surface.)
Temperature (°C)
(2) IRS Method (Mounting Solder: Lead-free)
Case top panel (peak):
255°C max.
Soldering
250 max.
230
-
180
150
Preheating
Relay terminal
section
120 max.
30 max.
Time (s)
(The temperature profile indicates the temperature on the PCB.)
6
Excessive amount of solder
Check the soldering in the actual mounting conditions before use.
20~30
Time (s)
G
6
K
2
F
R
F
V
Insufficient amount of solder
G6K-2F-RF-V
Surface-mounting High-frequency Relay
■Safety Precautions
●For general precautions on PCB Relays, refer to the precautions provided in General Information of the Relay Product
Data Book.
Correct Use
●Coating
●Relay Handling
• Use the Relay as soon as possible after opening the
moistureproof package. (As a guideline, use the Relay within
one week at 30°C or less and 60% RH or less.) If the Relay is
left for a long time after opening the moisture-proof package,
the appearance may suffer and seal failure may occur after the
solder mounting process. To store the Relay after opening the
moisture-proof package, place it into the original package and
seal the package with adhesive tape.
• When washing the product after soldering the Relay to a PCB,
use a water-based solvent or alcohol-based solvent and keep
the solvent temperature to less than 40°C. Do not put the
Relay in a cold cleaning bath immediately after soldering.
• Do not use silicone coating to coat the Relay when it is
mounted to the PCB. Do not wash the PCB after the Relay is
mounted using detergent containing silicone. Otherwise, the
detergent may remain on the surface of the Relay.
●Repeatability
• Contact your OMRON representative if the Relay will be used
in an application that requires high repeatability in highfrequency characteristics and contact resistance.
●Environmental Conditions for Usage, Storage, and
Transport
• Avoid direct sunlight when using, storing, or transporting the
Relay and maintain normal temperature, humidity, and
pressure conditions.
●Long-term, Continuous ON Contacts
G
6
K
2
F
R
F
V
-
• Using the Relay in a circuit where the Relay will be ON continuously
for long periods (rather than switching) can lead to unstable contacts
because the heat generated by the coil itself will affect the insulation
and can cause a film to develop on the contact surfaces. We
recommend using a latching relay (magnetic-holding relay) in this
kind of circuit. If a single-side stable model must be used in this kind
of circuit, we recommend adding fail-safe circuits in case the contact
fails or the coil burns out.
-
●Claw Securing Force During Automatic Mounting
• During automatic insertion of Relays, be sure to set the
securing force of each claw to the following so that the Relay’s
characteristics will be maintained.
C
A
B
Direction A: 1.96 N max.
Direction B: 4.90 N max.
Direction C: 1.96 N max.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K290-E1-01
0317(0317)(O)
7